Kupplungen - . . . SD7 Welle M8 x 1,25 - 21-00000
 
		
	N° Article
				21-00000
			Désignation
				I N F O
			Spécifications
				---
			N° original
				---
			Réfrigérant
				-
			N° OEM
				---
			Note
				G = Front groove position 
E = Ear width
M - M1 - M2 - M3 = Mounting dimensions
B = Bolts diameter
Standard speed: (except OEM specifications)
SD505, SD5H09 . . . 6500 r.p.m. continuous . . . 7500 r.p.m. maximum
SD5L09 . . . 3000 r.p.m. continuous . . . 4000 r.p.m. maximum
SD507, SD5H11, SD508, SD5H14, SD510 . . . STD models . . . 6000 r.p.m. continuous . . . 7000 r.p.m. maximum
SD508, SD5H14, SD510 . . . HD / SHD models . . . 4000 r.p.m. continuous . . . 6000 r.p.m. maximum
SD5L14 . . . 3000 r.p.m. continuous . . . 4000 r.p.m. maximum
SD708, SD709 . . . 6000 r.p.m. continuous . . . 7000 r.p.m. maximum
SD7H15 . . . STD models . . . 6000 r.p.m. continuous . . . 7000 r.p.m. maximum
SD7H15 . . . HD models . . . 4000 r.p.m. continuous . . . 6000 r.p.m. maximum
SD7H15 . . . SHD models . . . 4000 r.p.m. continuous . . . 4000 r.p.m. maximum
SD7L15 . . . 3000 r.p.m. continuous . . . 4000 r.p.m. maximum
Oil type and quantity: Always check OEM specifications or compressor label.
SD5H14 . . . SP-20 . . . 210 cm³
SD7H15 . . . SP-20 . . . 135 cm³ with TXV valve or 240 cm³ with orifice tube.
On systems with long hoses or dual evaporators, calculate the desired oil charge as below:
Oil amount (cm³) = [(Refrigerant charge in grams x 0.06) + 66] ÷ 0.9
			E = Ear width
M - M1 - M2 - M3 = Mounting dimensions
B = Bolts diameter
Standard speed: (except OEM specifications)
SD505, SD5H09 . . . 6500 r.p.m. continuous . . . 7500 r.p.m. maximum
SD5L09 . . . 3000 r.p.m. continuous . . . 4000 r.p.m. maximum
SD507, SD5H11, SD508, SD5H14, SD510 . . . STD models . . . 6000 r.p.m. continuous . . . 7000 r.p.m. maximum
SD508, SD5H14, SD510 . . . HD / SHD models . . . 4000 r.p.m. continuous . . . 6000 r.p.m. maximum
SD5L14 . . . 3000 r.p.m. continuous . . . 4000 r.p.m. maximum
SD708, SD709 . . . 6000 r.p.m. continuous . . . 7000 r.p.m. maximum
SD7H15 . . . STD models . . . 6000 r.p.m. continuous . . . 7000 r.p.m. maximum
SD7H15 . . . HD models . . . 4000 r.p.m. continuous . . . 6000 r.p.m. maximum
SD7H15 . . . SHD models . . . 4000 r.p.m. continuous . . . 4000 r.p.m. maximum
SD7L15 . . . 3000 r.p.m. continuous . . . 4000 r.p.m. maximum
Oil type and quantity: Always check OEM specifications or compressor label.
SD5H14 . . . SP-20 . . . 210 cm³
SD7H15 . . . SP-20 . . . 135 cm³ with TXV valve or 240 cm³ with orifice tube.
On systems with long hoses or dual evaporators, calculate the desired oil charge as below:
Oil amount (cm³) = [(Refrigerant charge in grams x 0.06) + 66] ÷ 0.9